Description
Materials:
- Body: Brass
- Shutter: Brass
- Compensator: Nikel-plated Brass
- Springs: AISI 304
- O-Rings: EPDM perox
- Sensor element : Copper and Brass
- Knob: ABS
- Outlet inner insert: POM-C anti-scale effect, preventing deposition”




/ drop pressure – mixing valve 1” LT 25_55shutter stroke 2 mm
flow rate (l/h) |
DP cold (mbar) |
DP hot (mbar) |
DP mix (H) (mbar) |
0 | 0 | 0 | 1 |
500 | 39 | 37 | 26 |
1000 | 153 | 143 | 103 |
1500 | 337 | 315 | 226 |
2000 | 597 | 558 | 400 |
2500 | 941 | 879 | 632 |
3000 | 1361,7 | 1273 | 914 |
Kv cold (DP 1bar) = 2,6 m3/h
Kv hot (DP 1bar) = 2,6 m3/h
Kv mix (DP 1bar) = 3,1 m3/h
Flow rate (DP 1bar) = 52 l/min
/ data sheet
Max working temperature 100°C
Working pressure 0,3 – 10 bar
Set point setting (outlet mix) 25- 55°C
Temperature stability +/-1°C
Benchmark of setting 30°C
shut-off anti-scald safety (30°C)