{"id":170,"count":3,"description":"<div id=\"contdesccat\">\r\n\t<div id=\"contdesccatimg\">\r\n\t\t<div id=\"desccatimg1\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/Intro-Contabilizzazione-01_340x570@72ppi.png\" alt=\"\" width=\"340\" height=\"570\" class=\"alignnone size-full wp-image-15188\" \/><\/div>\r\n\t\t<div id=\"desccatimg2\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/Intro-Contabilizzazione-02_340x275@72ppi.png\" alt=\"\" width=\"340\" height=\"275\" class=\"alignnone size-full wp-image-15190\" \/><\/div>\r\n\t\t<div id=\"desccatimg3\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/Intro-Contabilizzazione-03_340x275@72ppi.png\" alt=\"\" width=\"340\" height=\"275\" class=\"alignnone size-full wp-image-15192\" \/><\/div>\r\n\t<\/div>\r\n\t<h2 class=\"desccatttl1\">Energy metering and temperature control<\/h2>\r\n\t<p class=\"desccattxt1\">Modules for centralized heating systems.<\/p>\r\n\t<p class=\"desccattxt1\">Modules suitable for individual apartments of buildings with central heating system, useful for individual metering of energy consumption and the independent temperature control.<\/p>\r\n\t<div style=\"width: 100%; height: 20px; clear: left\"><\/div>\r\n\t<div id=\"contdesccattab\">\r\n\t\t<div class=\"contdesccattabttl\">Hydraulic components for energy metering modules<\/div>\r\n\t\t<div class=\"contdesccattabtxt\">\r\n\t\t<ol style=\"margin: 2px 0px 0px 15px;\">\r\n\t\t\t<li>MULTIFUNCTION 3-WAY VALVE<\/br>3-way valve for energy metering modules, with integrated bypass valve and flow rate adjustment<\/li>\r\n\t\t\t<li>HYDROBLOCK<\/br>Hydroblock for energy metering modules, local DHW production with plate heat exchanger<\/li>\r\n\t\t<\/ol>\r\n\t\t<\/div>\r\n\t\t<div class=\"contdesccattabimg1\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/INTRO_SAT-box01_r01.png\" alt=\"\" width=\"770\" height=\"570\" class=\"alignnone size-full wp-image-15200\" \/><\/div>\r\n\t\t<div style=\"width: 100%; height: 40px;\"><\/div>\r\n\t\t<div class=\"contdesccattabttl\">Application examples<\/div>\r\n\t\t<div class=\"contdesccattabtxt\">\r\n\t\t<p>Sat RSPT<\/p>\r\n\t\t<ul style=\"margin: 2px 0px 0px 15px;\">\r\n\t\t\t<li>Individual calorie metering CH<\/li>\r\n\t\t\t<li>Individual metering of cold and hot domestic water DHW<\/li>\r\n\t\t\t<li>Independent room temperature regulation<\/li>\r\n\t\t\t<li>Local production of domestic hot water with plate heat exchanger<\/li>\r\n\t\t\t<li>DHW  Temperature adjusting with thermostatic mixing valve<\/li>\r\n\t\t\t<li>Circulator on board<\/li>\r\n\t\t<\/ul>\r\n\t\t<\/div>\r\n\t\t<div class=\"contdesccattabimg2\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/INTRO_SAT-box02_r01.png\" alt=\"\" width=\"770\" height=\"370\" class=\"alignnone size-full wp-image-15210\" \/><\/div>\r\n\t\t<div class=\"contdesccattabtxt\">\r\n\t\t<p>Sat R<\/p>\r\n\t\t<ul style=\"margin: 2px 0px 0px 15px;\">\r\n\t\t\t<li>Individual calorie metering CH<\/li>\r\n\t\t\t<li>Individual metering of cold and hot domestic water DHW<\/li>\r\n\t\t\t<li>Independent room temperature regulation<\/li>\r\n\t\t\t<li>DHW temperature adjusting with thermostatic mixing valve<\/li>\r\n\t\t<\/ul>\r\n\t\t<\/div>\r\n\t\t<div class=\"contdesccattabimg2\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/INTRO_SAT-box03_r01.png\" alt=\"\" width=\"770\" height=\"370\" class=\"alignnone size-full wp-image-15214\" \/><\/div>\r\n\t\t<div class=\"contdesccattabtxt\">\r\n\t\t<p>Sat R2P<\/p>\r\n\t\t<ul style=\"margin: 2px 0px 0px 15px;\">\r\n\t\t\t<li>Management of 2 independent zones: low and high temperature<\/li>\r\n\t\t\t<li>Individual calorie metering CH<\/li>\r\n\t\t\t<li>Individual metering of cold and hot domestic water DHW<\/li>\r\n\t\t\t<li>Independent room temperature regulation<\/li>\r\n\t\t\t<li>Circulator on board<\/li>\r\n\t\t<\/ul>\r\n\t\t<\/div>\r\n\t\t<div class=\"contdesccattabimg2\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/INTRO_SAT-box04_r01.png\" alt=\"\" width=\"770\" height=\"370\" class=\"alignnone size-full wp-image-15216\" \/><\/div>\r\n\t\t<div class=\"contdesccattabtxt\">\r\n\t\t<p>Sat RSPTDS<\/p>\r\n\t\t<ul style=\"margin: 2px 0px 0px 15px;\">\r\n\t\t\t<li>Hydraulic separation between primary and secondary heating circuits with plate heat exchanger<\/li>\r\n\t\t\t<li>Individual calorie metering CH<\/li>\r\n\t\t\t<li>Individual metering of cold and hot domestic water DHW<\/li>\r\n\t\t\t<li>Independent room temperature regulation<\/li>\r\n\t\t\t<li>Local production of domestic hot water with plate heat exchanger<\/li>\r\n\t\t\t<li>DHW  Temperature adjusting with thermostatic mixing valve<\/li>\r\n\t\t\t<li>Circulator on board<\/li>\r\n\t\t<\/ul>\r\n\t\t<\/div>\r\n\t\t<div class=\"contdesccattabimg1\"><img src=\"https:\/\/otma.it\/wp-content\/uploads\/2021\/05\/INTRO_SAT-box05_r01.png\" alt=\"\" width=\"770\" height=\"370\" class=\"alignnone size-full wp-image-15218\" \/><\/div>\r\n\t\t<p style=\"margin: 0px; padding: 0px;\"><\/p>\r\n\t<\/div>\r\n<\/div>\r\n<p style=\"margin: 0px; padding: 0px; height: 24px;\"><\/p>","link":"https:\/\/otma.it\/en\/product-category\/energy-metering\/","name":"Energy metering","slug":"energy-metering","taxonomy":"product_cat","parent":0,"meta":[],"_links":{"self":[{"href":"https:\/\/otma.it\/en\/wp-json\/wp\/v2\/product_cat\/170"}],"collection":[{"href":"https:\/\/otma.it\/en\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/otma.it\/en\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"wp:post_type":[{"href":"https:\/\/otma.it\/en\/wp-json\/wp\/v2\/product?product_cat=170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}